SBG Design Works SHEET Q-01

Cover / Quick services / CSA F280 Heat Loss & Gain Report

Q-01 · Quick service

CSA F280 heat loss and gain report.

A room-by-room load calculation for a house, prepared to CSA F280-12 and delivered as a PDF report. Use it to size a heat pump or furnace, support a permit application, or check a contractor’s quote.

Starting fee
$650House, plus HST
Turnaround
5 daysBusiness days from complete information
Method
CSA F280-12Clauses 4–7
What you get
  • Room-by-room heat loss and heat gain
  • Building totals with ventilation and air leakage shown
  • Annex D summary sheet
  • Equipment capacity range for heating and cooling
  • Design conditions for the location
  • PDF report signed under BCIN 513381
When you need it
  • Replacing a furnace or baseboard heat with a heat pump
  • A township asks for a heat loss calculation
  • Checking a contractor’s equipment size
  • Planning an addition or a basement finish
  • A program or lender asks for a load calculation
What to send
  • Floor plans with dimensions, or a sketch
  • Window sizes and type
  • Insulation levels for walls, roof and basement
  • Ventilation — HRV, ERV or exhaust only
  • Site address
What the design accounts for

What the calculation covers

  • Envelope

    Walls, roof, floors, and foundation from the actual assemblies.

  • Glazing and orientation

    Window area, type, and the direction each one faces.

  • Air leakage

    Estimated from the air tightness of the house and the site’s wind exposure.

  • Ventilation

    The ventilation load, net of heat recovery where an HRV is installed.

  • Foundation losses

    Basement and slab-on-grade losses using the CSA foundation methods.

  • Design weather

    Heating and cooling design temperatures for the location.

Process

How it works

  1. Send the drawings

    Plans, site information, and what you need. Upload links and PDFs are fine.

  2. Confirm scope and fee

    You get a fixed fee and a delivery date, usually the same business day. Nothing starts until you approve it.

  3. Design and check

    Calculations and drawings prepared to the 2024 Ontario Building Code, then checked before issue.

  4. Receive the package

    Signed drawings and calculations under BCIN 513381, ready to submit. Questions from the first review are answered.

Price and turnaround

Price and turnaround

Quick service
RefServiceFee
QS-01CSA F280 heat loss & gain report — housefrom $650
RSH-01Rush — 2 business days+25 – 40%

All fees plus HST. Payment Net 14 by e-transfer. Referred work gets priority scheduling. The fee is confirmed in your quote before work begins.

Houses over 3,000 sq ft, or with complex additions, are quoted from the drawings. Ordering the full HVAC package later? The calculation carries straight into it.

Questions

Frequently asked

How is this different from the full HVAC package?

The report gives the loads and equipment capacity range. The full package adds duct design, ventilation design, and permit drawings.

Can this size a heat pump?

Yes. The report gives the heating load at the local design temperature, so the heat pump’s capacity at that temperature can be checked against it.

Do you need to visit the house?

Usually not. Plans or a measured sketch with window sizes and insulation levels are enough. A site visit can be quoted if no drawings exist.

Next step

Ready to order?

Send what you have. You’ll get a fixed fee and a delivery date before any work starts.