SBG Design Works SHEET M-01

Cover / HVAC

M-01 · Building services

HVAC design based on your building.

CSA F280 heat loss and heat gain, equipment selection, duct design, ventilation, and SB-12 energy compliance for houses and small buildings across the Parry Sound and Nipissing districts.

Starting fee
$1,000House, plus HST
Turnaround
10–14 daysBusiness days from complete site information
Load method
CSA F280-12Room by room
What you get
  • Room-by-room heat loss and heat gain report
  • Equipment selection and sizing
  • Duct layout, trunk and branch sizing
  • Ventilation and HRV design
  • Combustion and make-up air check
  • SB-12 compliance documentation
When you need it
  • New house or addition
  • Heat pump replacing a furnace or baseboard heat
  • Basement finish with new ductwork
  • Township asks for a heat loss calculation
  • Small commercial fit-out
What to send
  • Floor plans and sections
  • Window sizes or a window schedule
  • Wall, roof and foundation assemblies
  • Proposed equipment, if chosen
  • Site address
Conceptual house floor plan with supply ducts and a return air path. Illustrative example, not for construction.
Duct layout conceptIllustrative example — not a completed client project or construction document.
View full size ↗

A sample CSA F280 calculation is available: open the sample report (teaching example, not a client project).

Building-specific calculations

Start with the building and its heating needs.

Equipment selection starts with the building envelope and local design conditions. A room-by-room load calculation provides a basis for sizing the system and planning its distribution.

CSA F280 calculations consider assemblies, glazing, orientation, infiltration, and the design temperature for the location. The results support equipment selection and the permit submission.

For cold-climate heat pumps, the design also considers the balance point and backup heating strategy so the equipment selection reflects how the system will be used.

What the design accounts for

What the package contains

  • Heat loss and heat gain to CSA F280

    Room-by-room loads from the real assemblies and the design conditions for this location. Delivered as a calculation you can hand to the examiner and to the supplier.

  • Equipment selection and sizing

    Furnace, boiler, air handler, cold-climate heat pump, or hybrid — sized to the calculated load with the balance point and backup strategy stated where a heat pump is involved.

  • Duct layout and sizing

    Supply and return runs, trunk and branch sizing, register selection and placement, return air paths, and static pressure are considered together.

  • Ventilation and HRV design

    Principal ventilation rate, HRV or ERV selection, duct routing, and distribution coordinated with the building envelope and Part 9 ventilation requirements.

  • Combustion and make-up air

    Combustion air supply, depressurization allowance for solid fuel appliances, kitchen exhaust make-up air, and spillage susceptibility considered for the proposed appliances and building.

  • Energy compliance

    SB-12 prescriptive or performance compliance path documented for the applicable climate zone, coordinated with the envelope so the mechanical package and the building permit tell the same story.

  • Small buildings and commercial

    Part 3 and Part 6 mechanical for small commercial, institutional, and multi-unit work — clinic and retail fit-outs, shops, garages with a business in them. Fire detection, lighting, and emergency power design are covered under the same Building Services qualification. Work that needs a professional engineer's seal is coordinated with one.

Process

How it works

  1. Send the drawings

    Plans, site information, and what you need. Upload links and PDFs are fine.

  2. Confirm scope and fee

    You get a fixed fee and a delivery date, usually the same business day. Nothing starts until you approve it.

  3. Design and check

    Calculations and drawings prepared to the 2024 Ontario Building Code, then checked before issue.

  4. Receive the package

    Signed drawings and calculations under BCIN 513381, ready to submit. Questions from the first review are answered.

Price and turnaround

HVAC pricing

The tier is set by building class: Part 9 house, or small building and commercial.

Mechanical permit design
RefServiceFee
HVA-01HVAC package with design loads — house$1,000 – $1,800
HVA-02HVAC package — small building or commercial$2,500 – $5,000
CMB-01Two or more trades on one projectdeduct 10%
RSH-01Rush turnaround — 5 business days+25 – 40%
REV-01Revision or resubmission after the first review cycle$350 – $600

All fees plus HST. Payment Net 14 by e-transfer. Referred work gets priority scheduling. The fee is confirmed in your quote before work begins.

Standard turnaround 10–14 business days from complete information. Need the load calculation only? See the F280 heat loss & gain report.

Questions

Frequently asked

Why not size equipment by square footage?

Two houses of the same size can have very different loads, depending on insulation, windows, orientation, and air tightness. A CSA F280 calculation sizes the equipment to the building, which matters most for heat pumps.

Can you size a cold-climate heat pump?

Yes. The design states the heating load at the local design temperature, the balance point, and the backup heat needed below it.

Can I get just the load calculation?

Yes. The F280 heat loss & gain report is a quick service, delivered in 5 business days.

Do you do small commercial work?

Yes. The Building Services qualification covers Part 3 and Part 6 mechanical within the BCIN scope, plus detection, lighting, and power. Work that needs a professional engineer’s seal is coordinated with one.

Do you supply or install equipment?

No. This is a design service. Your HVAC contractor supplies and installs to the drawings.

Next step

Ready to order?

Send what you have. You’ll get a fixed fee and a delivery date before any work starts.